2 Arm UV-C Disinfection Trolley

The UV-C trolley is designed to disinfect surfaces up to 36m2 of circular coverage area or 20m2 of square area. In laboratory testing, Signify’s UV-C light sources reduced SARS-CoV-2 virus infectivity on a surface to below detectable levels in as few as 9 seconds.

1Safety features; remote control, voice alarm and key locks, are integrated to operate the trolley safely. With the 360° wheels, UV-C trolley is a flexible solution as it can be easily and quickly repositioned in a room/space. The UV-C radiation of the trolley disinfects with listed time slot and offers a great variety for options of lamp directions and disinfection durations.

Philips UVC T210 2-Arm UVC Trolley with 360° sensor detection. 4 x 30W TUV lamps

Order code: 919013004771


 

Benefits

  • In laboratory testing, Signify’s UV-C light sources reduced SARS-CoV-2 virus infectivity on a surface to below detectable levels in as few as 9 seconds1.
  • 4-log disinfection for 20m2 square area or 36m2 circular area within 15 minutes for two arm trolley2.

 


 

Applications include:

  • Office
  • School
  • Banking
  • Hospitality
  • Food outlets
  • Hair and beauty salons
  • Buses and trains

 


 

Features:

  • Remote control: on / off independent button, 4 options 15 / 30 / 60 / 90 mins. 30 sec delay time before disinfection cycle commences.
  • Control distance: maximum 10 meters.
  • Housing material: stainless steel with plastic which is anti UV.
  • Two Philips UV-C lamp: strong ultraviolet radiation. Two arm trolley – 4pcs TUV 30W.
  • Lock and key protection: only authorized person(s) can unlock the key to operate the trolley according to safety instruction.
  • Voice: operation is supported by audio guidance on the warnings and procedures of the trolley.
  • Touch panel: timer button 15 / 30 / 60 / 90 / 120 mins, power on / off button, 30 sec delay time when timing is setting

 


 

1Nadia Storm et al, Rapid and complete inactivation of SARS-CoV-2 by ultraviolet-C irradiation, 2020. Subject to peer review and available only as a pre-print at www.researchsquare.com/article/rs-65742/v2. The UV-C irradiance used in this study was 0.849 mW/cm2.

2The 4-log disinfection dose for Covid19 is 220J/m2 which is verified to calculate the Irradiance at the distance of below mentioned coverage area: 0.13W/m2.
Time = Dose / Irradiance = 220(J/m2) / 0.13(W/m2) = 1692(S) / 60=28 (mins).

 


 

Download product data sheet


 

DANGER: Risk Group 3 – Ultraviolet Product
These UV-C products are meant for disinfection purposes only and cannot be used for general illumination. The products generate high power UV-C light, which can cause serious injuries to eyes and/or skin. Avoid direct exposure of eyes and skin to the UV-C light. Only for use in closed enclosures, which protect users from UV-C light exposure.
In case of lamp breakage, follow instructions: ventilate the room for 30 minutes and remove loose parts, preferably wearing gloves. Pack broken parts in a closed packaging (plastic bag) and dispose of as chemical waste. Do not use a vacuum cleaner.